NCI temperature effectsTemperature effects adjust tree growth based on mean annual temperature. Note: If these effects are used with NCI Mortality, the time period unit for parameters must match the value specified in the NCI Parameter Period (years) parameter. 
 Weibull temperature effectParameters| Weibull Temperature Effect "A" | The A parameter for the temperature effect. The effect is based on mean annual temperature in degrees Celsius. |  | Weibull Temperature Effect "B" | The B parameter for the temperature effect. The effect is based on mean annual temperature in degrees Celsius. |  | Weibull Temperature Effect "C" | The C parameter for the temperature effect. The effect is based on mean annual temperature in degrees Celsius. |  
 How it worksTemperature Effect is calculated as: TE =  where: - A is the Weibull Temperature Effect "A" parameter
 - B is the Weibull Temperature Effect "B" parameter
 - C is the Weibull Temperature Effect "C" parameter
 - T is the plot's annual mean temperature, in degrees Celsius, as entered for the Plot
 
 
 Double logistic temperature effectParameters| Double Logistic Temp Effect "al" | The al parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  | Double Logistic Temp Effect "bl" | The bl parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  | Double Logistic Temp Effect "cl" | The cl parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  | Double Logistic Temp Effect "ah" | The ah parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  | Double Logistic Temp Effect "bh" | The bh parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  | Double Logistic Temp Effect "ch" | The ch parameter for the temperature effect. The effect is based on mean annual temperature in degrees Kelvin. |  
 How it worksTemperature Effect is calculated as:  where: - al is the Double Logistic Temp Effect "al" parameter
 - bl is the Double Logistic Temp Effect "bl" parameter
 - cl is the Double Logistic Temp Effect "cl" parameter
 - ah is the Double Logistic Temp Effect "ah" parameter
 - bh is the Double Logistic Temp Effect "bh" parameter
 - ch is the Double Logistic Temp Effect "ch" parameter
 - T is the plot's annual mean temperature, in degrees Kelvin. This is calculated from the value in degrees C in the Plot
 
  |